| Fixation |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Intrusion attempt |
|
|
|
|
| Intrusion resistance | ENV 1627 - 1999 | Resistance class: 3 |
|
5min |
| Test specification | ENV 1630 - 1999 | Tool set B |
|
|
|
|
|
|
|
|
| Effraction |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Intrusion attempt |
|
|
|
|
| Tear-out resistance | No specified standard | 100000 N at 1.5m height |
|
20 minutes |
|
|
|
|
|
|
| Climatic |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Functional climatic qualification |
|
|
|
|
| Dry cold temperature | IEC 60068-2-1 - 1995 | -30°C | Before, During and After the test | 16h |
| Dry heat temperature | IEC 60068-2-2 - 1993 | 45°C | Before, During and After the test | 16h |
| Dry temperature - Cyclic | EN 60068-2-14 - 2000 | -30°C / +45°C | Before, During and After the test | 3h |
| Damp heat temperature | IEC 60068-2-3 | 35°C / 95%HR | Before, During and After the test | 16h |
| Damp heat temperature - Cyclic | IEC 60068-2-30 - 1999 | 20°C to 35°C / 95%HR | Before, During and After the test | 2x12h |
| Storage cold temperature | IEC 60068-2-48 - 1999 | -30°C | Before, During and After the test | 96h |
| Storage heat temperature | IEC 60068-2-48 - 2000 | 60°C | Before, During and After the test | 96h |
| Solar Radiation |
|
|
|
|
| Solar Radiation | ? | Solar radiation: 1120W/m2 | Before, During and After the test | Functional tests to be done after 16h of stabilisation |
|
|
|
External Temperature: 45°C |
|
|
| Salted spray |
|
|
|
|
| Salted spray resistance | NFC 20711 | Ka test | Test on relevant terminal samples (material + paint plates, external accessories...). | 96h |
|
|
|
|
|
|
| Protection |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Dust and water Protection Index |
|
|
|
|
| Dust and water | EN 50529 - 1992 (IEC 60529 ?) | IP54 and IP33 for openings | IP5X cat 2 (no depression for dust) |
|
| Cleaning Solvents |
|
|
|
|
| Cleaning water & denatured isopropyl alcohol |
|
|
|
|
|
|
|
|
|
|
| Sécurité |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Electrical safety |
|
|
|
|
|
|
EN 60 950 | Electrical hazards |
|
|
|
|
|
Mechanical hazards |
|
|
|
|
|
Fire hazards |
|
|
|
|
|
Thermal hazards |
|
|
|
|
|
|
|
|
| Vandalisme |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Vandalism |
|
|
|
|
| Mechanical pulling resistance | No specified standard | 1000 N at a height of 1.5 metres |
|
|
| Mechanical pressure resistance | No specified standard | 800 N on 5 cm2 |
|
|
| Mechanical impacts | EN 50102 | IK10 (20J) | 5 impacts on each concerned part (maximum 3 of them at the same location) |
|
| Mechanical shocks | IEC 60068-2-27 1994 | 5G | 3 shocks per direction (6 directions) | 11ms half sinus |
|
|
|
|
|
|
| Vibrations |
|
|
|
|
| Type of test | Standard | Severity | Functional checkout | Duration |
| Fixed equipment |
|
|
|
|
| Random vibration wide brand | IEC 60068-2-64 | From 10-150Hz - 0,5G rms - ASD Level 0,005 | Before, During and After | 30 min on each axis |
| Sinusoïdal vibration | IEC 60068-2-6 1995 | From 10-150Hz - 0,5G - Sweep 20/axis | Before, During and After | ? |
| Sinusoïdal vibration | IEC 60068-2-6 1995 | RDF 1g (10-150Hz) - G level 2gn2 - Sweep 20/axis | Before, During and After | ? |
| Resonance frequency detection and suppression (RDF) | CEI 68-2-6 - 1987 (IEC60068-2-6 1995 ?) | from 3 to 200Hz on the 3 axes |
|
|
| Operation during vibrations | CEI 68-2-6 - 1987 (IEC60068-2-6 1995 ?) | 4M3 | Before, during and after the test | A |
| Transport / Packaged equipment | MIL STD 810E | Method 514.5, level?, type of transport? | Before / After the test | A, US Highway truck vibration exposures, figure 514. 5C-1 |