Fixation
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Intrusion attempt
|
|
|
|
|
|
Intrusion resistance
|
ENV 1627 - 1999
|
Resistance class: 3
|
|
5min
|
|
Test specification
|
ENV 1630 - 1999
|
Tool set B
|
|
|
|
|
|
|
|
|
Effraction
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Intrusion attempt
|
|
|
|
|
|
Tear-out resistance
|
No specified standard
|
100000 N at 1.5m height
|
|
20 minutes
|
|
|
|
|
|
|
Climatic
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Functional climatic qualification
|
|
|
|
|
|
Dry cold temperature
|
IEC 60068-2-1 - 1995
|
-30°C
|
Before, During and After the test
|
16h
|
|
Dry heat temperature
|
IEC 60068-2-2 - 1993
|
45°C
|
Before, During and After the test
|
16h
|
|
Dry temperature - Cyclic
|
EN 60068-2-14 - 2000
|
-30°C / +45°C
|
Before, During and After the test
|
3h
|
|
Damp heat temperature
|
IEC 60068-2-3
|
35°C / 95%HR
|
Before, During and After the test
|
16h
|
|
Damp heat temperature - Cyclic
|
IEC 60068-2-30 - 1999
|
20°C to 35°C / 95%HR
|
Before, During and After the test
|
2x12h
|
|
Storage cold temperature
|
IEC 60068-2-48 - 1999
|
-30°C
|
Before, During and After the test
|
96h
|
|
Storage heat temperature
|
IEC 60068-2-48 - 2000
|
60°C
|
Before, During and After the test
|
96h
|
|
Solar Radiation
|
|
|
|
|
|
Solar Radiation
|
?
|
Solar radiation: 1120W/m2
|
Before, During and After the test
|
Functional tests to be done after 16h of stabilisation
|
|
|
External Temperature: 45°C
|
|
|
|
Salted spray
|
|
|
|
|
|
Salted spray resistance
|
NFC 20711
|
Ka test
|
Test on relevant terminal samples (material + paint plates, external accessories...).
|
96h
|
|
|
|
|
|
|
Protection
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Dust and water Protection Index
|
|
|
|
|
|
Dust and
water
|
EN 50529 - 1992 (IEC 60529 ?)
|
IP54 and IP33 for openings
|
IP5X cat 2 (no depression for dust)
|
|
|
Cleaning Solvents
|
|
|
|
|
|
Cleaning water & denatured isopropyl alcohol
|
|
|
|
|
|
|
|
|
|
|
Sécurité
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Electrical safety
|
|
|
|
|
|
EN 60 950
|
Electrical hazards
|
|
|
|
|
Mechanical hazards
|
|
|
|
|
Fire hazards
|
|
|
|
|
Thermal hazards
|
|
|
|
|
|
|
|
|
Vandalisme
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Vandalism
|
|
|
|
|
|
Mechanical pulling resistance
|
No specified standard
|
1000 N at a height of 1.5 metres
|
|
|
|
Mechanical pressure resistance
|
No specified standard
|
800 N on 5 cm2
|
|
|
|
Mechanical impacts
|
EN 50102
|
IK10 (20J)
|
5 impacts on each concerned part (maximum 3 of them at the same location)
|
|
|
Mechanical shocks
|
IEC 60068-2-27 1994
|
5G
|
3 shocks per direction (6 directions)
|
11ms half sinus
|
|
|
|
|
|
|
Vibrations
|
|
|
|
|
|
Type of test
|
Standard
|
Severity
|
Functional checkout
|
Duration
|
|
Fixed equipment
|
|
|
|
|
|
Random vibration wide brand
|
IEC 60068-2-64
|
From 10-150Hz - 0,5G rms - ASD Level 0,005
|
Before, During and After
|
30 min on each axis
|
|
Sinusoïdal vibration
|
IEC 60068-2-6 1995
|
From 10-150Hz - 0,5G - Sweep 20/axis
|
Before, During and After
|
?
|
|
Sinusoïdal vibration
|
IEC 60068-2-6 1995
|
RDF 1g (10-150Hz) - G level 2gn2 - Sweep 20/axis
|
Before, During and After
|
?
|
|
Resonance frequency detection and suppression (RDF)
|
CEI 68-2-6 - 1987 (IEC60068-2-6 1995 ?)
|
from 3 to 200Hz on the 3 axes
|
|
|
|
Operation during vibrations
|
CEI 68-2-6 - 1987 (IEC60068-2-6 1995 ?)
|
4M3
|
Before, during and after the test
|
A
|
|
|
|
|
|
|
|
Transport / Packaged equipment
|
MIL STD 810E
|
Method 514.5, level?, type of transport?
|
Before / After the test
|
A, US Highway truck vibration exposures, figure 514. 5C-1
|
Commentaires